When you are calibrating equipment, you will probably want to account for temperatures associated with the system.  Here is some information about temperature measurement that might help you better understand.

The majority of physical processes are affected, to one degree or another, by temperature.  Whether these changes are exploited as a technique for temperature transduction or used to identify temperature induced artifacts, the measurement of temperature is of fundamental importance.  Some physical effects used as the basis for temperature transduction are listed below:

  1. Thermal expansion
  2. Thermocapacitive effect
  3. Thermochemical effect
  4. Thermoelectric effect
  5. Thermoresistive effect
  6. Pyroelectric effect
  7. Radiation effect

Thermal expansion is the basis for function of mercury or alcohol thermometers while thermocouples employ the thermoelectric effect.  Like the resistance temperature detector (RTD), the thermistor is also a temperature sensistive resistor.  Thermistor is an acronym for thermally sensitive resistors.  While the thermocouple is the most versatile temperature transducer and the Platinum RTD is the most table, the word that best describes the thermistor is sensitive.

Of the three major categories of sensors, the thermistor exhibits by far the largest parameter change with temperature.   Thermistors are generally composed of semiconductor materials.  Although positive temperature coefficient units are available, most thermistors have a negative temperature coefficient (TC); that is, their resistance decreases with increasing temperature.  The negative T.C. can be as large as several percent per degree Celsius, allowing the thermistor circuit to detect minute changes in temperature, which could not be observed with an RTD or thermocouple circuit.  The price we pay for this increased sensitivity is loss of linearity.  The thermistor is an extremely non-linear device that is highly dependent upon process parameters.  Consequently, manufacturers have not standardized thermistor curves to the extent that RTD and thermocouple curves have been standardized.

An individual thermistor curve can be very closely approximated through the use of the Steinhart-Hart Equation:

\frac{1}{T_{i}} = A + BlnR_{i} + C(lnR_{i})^{3}

Here,

T_{i} = temperature in degrees kelvin for i = 1,…,n (number of data points),

R_{i} = resistance of the thermistor (ohms) for i = 1,…,n, and

A, B, C = Curve-fitting coefficients.

The choice of temperature transduction technique depends on a variety of factors, including temperature range, cost, size, weight, power consumption, sensitivity, aging effects, etc.  Another prime consideration that affects a choice is the range over which measurements are to be made and the precision of the readings.  Other considerations that may not be so obvious include selection of a thermal mass to be compatible with the bandwidth requirements of the anticipated temperature variations.

Related Blogs

  • Share/Bookmark

Tags: , , , , ,

You must be logged in to post a comment.

ballssmall
 

You need to log in to vote

The blog owner requires users to be logged in to be able to vote for this post.

Alternatively, if you do not have an account yet you can create one here.

Powered by Vote It Up

Copyright © 2010 EngineerSphere.com All rights reserved .
Sitemap      Jeff Schuler